DocumentCode
3772593
Title
Detection of insulation deterioration through electrical spectrum analysis
Author
James E. Timperley
Author_Institution
American Electric Power Service Corporation, Canton, Ohio 44701
fYear
1983
Firstpage
60
Lastpage
64
Abstract
Several types of insulation deterioration common to large rotating electrical machines produce Electromagnetic Interference (EMI) at discrete frequencies or within bands of frequencies. This paper employs the use of standing wave calculations to predict these natural resonant points. Curves of measured impedance variation with frequency are presented to verify calculated values. Determination of these resonants is an important first step in real time monitoring and later physically locating a defect before failures occur.
Keywords
"Resonant frequency","Stators","Conductors","Impedance","Frequency measurement","Insulation","Electromagnetic interference"
Publisher
ieee
Conference_Titel
Electrical/Electronical Insulation Conference, 1983 EIC 6th
Print_ISBN
978-1-5090-3114-6
Type
conf
DOI
10.1109/EEIC.1983.7465033
Filename