DocumentCode :
3772612
Title :
Experience and practice with standardized acceptance test procedures for windings of rotating machinery
Author :
Hartmut Meyer;Arnold Wichmann
Author_Institution :
Siemens AG, Berlin, Germany
fYear :
1983
Firstpage :
146
Lastpage :
151
Abstract :
European Standards for rotating machines include rules for acceptance tests on high voltage winding insulation. The standard claims for dielectric loss and dielectric strength measurements and contains a thermal short time stability test of single bars or coils. This paper describes the test methods and the values of the acceptance limits. Examples will be shown how dielectric loss measurements serve successfully as a tool for maintaining uniform manufacturing results using different methods of modern insulation production. Problems, limits and benefits of applicating the described test procedures will be discussed and an international standard recommended.
Keywords :
"Insulation","Coils","Voltage measurement","Standards","Bars","Windings","Dielectric loss measurement"
Publisher :
ieee
Conference_Titel :
Electrical/Electronical Insulation Conference, 1983 EIC 6th
Print_ISBN :
978-1-5090-3114-6
Type :
conf
DOI :
10.1109/EEIC.1983.7465052
Filename :
7465052
Link To Document :
بازگشت