• DocumentCode
    3772638
  • Title

    A new thermal aging facility for the evaluation of generator stator insulation systems

  • Author

    H. N. Galpern

  • Author_Institution
    Medium Steam Turbine Department, General Electric Company, Lynn, Massachusetts
  • fYear
    1983
  • Firstpage
    258
  • Lastpage
    263
  • Abstract
    A new test facility has been built to assess the effect of long-term cyclic duty on generator armature insulation systems. In this facility it is possible to isothermally age or thermally cycle armature insulation systems in simulation of base-load or cycling service conditions. Results obtained from a three-year aging program on two service-proven base-load insulation systems are presented.
  • Keywords
    "Aging","Insulation","Temperature measurement","Generators","Isothermal processes","Temperature distribution","Bars"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronical Insulation Conference, 1983 EIC 6th
  • Print_ISBN
    978-1-5090-3114-6
  • Type

    conf

  • DOI
    10.1109/EEIC.1983.7465078
  • Filename