• DocumentCode
    3772654
  • Title

    Dynamometer test of induction motors rewound using Wanlass redesign techniques

  • Author

    Charles A. Koffler

  • Author_Institution
    President &
  • fYear
    1983
  • Firstpage
    336
  • Lastpage
    338
  • Abstract
    Tests of squirrel cage induction motors rewound to the so-called Wanlass redesign were made using dynamometers to evaluate energy savings over conventionally wound motors. Results of these tests are outlined. It was concluded that final motor efficiencies are not predictable and that a reduction in efficiency sometimes resulted.
  • Keywords
    "Testing","Induction motors","Windings","Capacitors","Maintenance engineering","Electric motors","Stator windings"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronical Insulation Conference, 1983 EIC 6th
  • Print_ISBN
    978-1-5090-3114-6
  • Type

    conf

  • DOI
    10.1109/EEIC.1983.7465094
  • Filename