Title :
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Author :
M. Osipenko;F. Pompili;M. Ripani;M. Pillon;G. Ricco;B. Caiffi;R. Cardarelli;G. Verona-Rinati;S. Argiro
Author_Institution :
Istituto Nazionale di Fisica Nucleare, Genoa, 16146 Italy
fDate :
4/1/2015 12:00:00 AM
Abstract :
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a 6Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 108 n/cm2s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 106 n/cm2s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 109 n/cm2s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
Keywords :
"Neutrons","Diamonds","Detectors","Inductors","Crystals","Radiation effects","Energy resolution"
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2015 4th International Conference on
DOI :
10.1109/ANIMMA.2015.7465605