DocumentCode :
3772853
Title :
Neutron detection with large plastic scintillators for RPM applications
Author :
G. Corre;K. Boudergui;G. Sannie;V. Kondrasovs
Author_Institution :
CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif Sur Yvette, France
fYear :
2015
fDate :
4/1/2015 12:00:00 AM
Firstpage :
1
Lastpage :
4
Abstract :
Homeland security requests the use Radiation Portal Monitor (RPM) to detect and differentiate gamma and neutron radiation. Gamma detection is required for illicit transportation of radioactive matter detection. Neutron detection is important to control nonproliferation of enriched material. Manufacturers worldwide propose sensors based on 3He which give the actual state of art in term of neutron detection. The price fluctuations due to the announcement of the shortage of 3He forces manufacturers to find viable alternative. From 10 years sensors providers have the challenge to replace previous 3He detectors that are known to be the most commonly deployed neutron sensor. As 3He detectors can only detect neutron, they must be completed with gamma detector. The proposed approach is based on pulse time correlation between adjacent sensors from signal collected by EJ200 plastic scintillators to detect gamma and neutron. Results obtained during FP7 Scintilla project test campaigns show the system relevance for replacement of today´s 3He detectors.
Keywords :
"Neutrons","Detectors","Plastics","Portals","Mesons"
Publisher :
ieee
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2015 4th International Conference on
Type :
conf
DOI :
10.1109/ANIMMA.2015.7465625