• DocumentCode
    3772907
  • Title

    The role of trace organic impurities in the initiation of electrical discharge

  • Author

    W. G. Hespenheide;K. B. Jesch

  • Author_Institution
    Burroughs Corporation, Paoli, Pennsylvania, United States of America
  • fYear
    1963
  • Firstpage
    84
  • Lastpage
    86
  • Abstract
    The breakdown of small spark gaps in air is not generally considered a predictable or controllable phenomenon; statistical time lag and breakdown voltage may vary by orders of magnitude. Typical test data for physically identical 0,002-inch gaps are shown in Figure 1. This represents the state of the art of two years ago.
  • Keywords
    "Impurities","Sparks","Cathodes","Platinum","Discharges (electric)","Spark gaps"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, Annual Report 1963 Conference on
  • Print_ISBN
    978-1-5090-3119-1
  • Type

    conf

  • DOI
    10.1109/EIC.1963.7466560
  • Filename
    7466560