DocumentCode
3773235
Title
Comparison of the effect of varnish treatment processes on the moisture resistance of electrical insulation systems for random wound motors
Author
R. J. Flaherty;J. A. Kimball;J. F. Tobin
Author_Institution
Naval Ship Research and Development Center, Annapolis, Maryland
fYear
1973
Firstpage
126
Lastpage
130
Abstract
Moisture and associated contaminates such as dirt and salt, can cause failure of electrical insulation by bridging cracks in embrittled insulation or cause failure by providing paths to ground. Previous Navy work reported by Flaherty and Walker 1 showed that failures can be moved into the end turns of windings by lap folding the slot cells to provide a long path to ground. In the 1961 report insulation systems were given a rating in accordance with their moisture resistance with the totally encapsulated winding providing the best protection. This study was followed by later work by Flaherty, Tobin and Walker2-3 in 1968 which compared varnish procedures using conventional solvent type varnishes and 100% solids varnishes using the trickle process. This work showed that the trickle process provided moisture protection equivalent to three dips and bakes in the solvent type varnish.
Keywords
"Stators","Windings","Solvents","Solids","Insulation","Glass","Commutation"
Publisher
ieee
Conference_Titel
Electrical Insulation Conference, 1973 EIC 11th
Print_ISBN
978-1-5090-3110-8
Type
conf
DOI
10.1109/EIC.1973.7468662
Filename
7468662
Link To Document