Abstract
With the recognition of overload resistance as a distinct and separate property, much has been added to the knowledge of magnet wire film performance. While various investigations1–5 have resulted in the classification of film insulations according to their resistance to overload, it has also been learned6–8 that this property does not necessarily correlate with long term thermal stability.