Title
Insulation systems for particle accelerator and associated magnets
Author
Ben Zimmerman;Marvin M. Fromm
Author_Institution
National Electric Coil Co., Columbus, Ohio
fYear
1967
Firstpage
285
Lastpage
287
Abstract
Insulation systems for coils used in particle accelerator and associated magnets are selected to meet particular electrical and mechanical requirements. Voltage range from 6 volts to 10 kv to ground. Mechanical requirements vary with the size of the coil, magnetic forces, and the pressure required for mounting the coils on cores. In addition, many coils are exposed to radiation of various types and intensity.
Keywords
"Coils","Insulation","Glass","Conductors","Resistance","Epoxy resins"