Title :
Electrical properties of ML and A.I.220 insulations on 2 mil and 5 mil cupron and tophel wires
Author_Institution :
General Atomic Division of General Dynamics Corporation, P.O. Box 608, San Diego, California
Abstract :
A program was conducted to find an insulation suitable for 2 mil diameter cupron and tophel wire f that could operate at ∼ 470°F for a minimum of 5 years in an argon gas environment. The applied voltage on the insulation is 6 volts. The cupron and tophel wires are used as the respective “P” and “N” legs in a radioisotope powered thermoelectric generator designated SNAP-15A.‡
Keywords :
"Wires","Insulation","Current measurement","Argon","Heating","Temperature","Temperature measurement"
Conference_Titel :
Electrical Insulation Conference, 1967 Seventh
Print_ISBN :
978-1-5090-3106-1
DOI :
10.1109/EIC.1967.7468835