• DocumentCode
    3773993
  • Title

    Analytic Method for Treating Data of Liquid Limit and Plastic Limit

  • Author

    Xiao Dong-Zhang;Jian Qiao-Li;Zou Meng

  • Author_Institution
    Key Lab. of Bionic Eng., Jilin Univ., Changchun, China
  • fYear
    2015
  • fDate
    6/1/2015 12:00:00 AM
  • Firstpage
    197
  • Lastpage
    200
  • Abstract
    Analytic method was one of treating the test data of liquid and plastic limit combined test. On the basis of analytic method, a "Liquid Limit and Plastic Limit Data Treating System" was developed using the object-oriented visual programming tool Microsoft Visual C++6.0. Flowchart and pseudo code of liquid and plastic treating procedure corresponding to "JTG E40-2007, cone penetrator 100g" was showed that switch statement and if statement were the main algorithm of treating procedure. Second level select nested structure was taken as main structure frame of treating procedure. In order to test and verify the validity of this treating system. The original data of liquid and plastic limit were received from liquid and plastic limit combined test and the original data was treated with Excel software and liquid limit and plastic limit data treating system. The comparison indicated that liquid limit and plastic limit data treating system improved efficiency and accuracy evidently.
  • Keywords
    "Liquids","Soil","Plastics","Mathematical model","Visualization","Software","Standards"
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Computation Technology and Automation (ICICTA), 2015 8th International Conference on
  • Type

    conf

  • DOI
    10.1109/ICICTA.2015.57
  • Filename
    7473269