• DocumentCode
    3775485
  • Title

    Engineering the Alcator C-Mod MSE diagnostic: Solutions to reactor-relevant diagnostic challenges

  • Author

    R. T. Mumgaard;S. D. Scott

  • Author_Institution
    MIT Plasma Science and Fusion Center, Cambridge, United States
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    Deploying precise optical diagnostics in harsh reactor environments poses significant engineering challenges including limited access, large forces, time-varying systematic errors, reflections, low signal-to-background levels and a need for in-situ calibration. Fielding a polarization-based Motional Stark Effect (MSE) diagnostic on Alcator C-Mod has proven to be difficult due to similar challenges, which has led to the development of solutions that enable polarization angle measurements with an accuracy of 0.2 degrees.
  • Keywords
    "Calibration","Plasmas","Systematics","Lenses","Optical polarization","Optical reflection","Robots"
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering (SOFE), 2015 IEEE 26th Symposium on
  • Electronic_ISBN
    2155-9953
  • Type

    conf

  • DOI
    10.1109/SOFE.2015.7482261
  • Filename
    7482261