Title :
Engineering the Alcator C-Mod MSE diagnostic: Solutions to reactor-relevant diagnostic challenges
Author :
R. T. Mumgaard;S. D. Scott
Author_Institution :
MIT Plasma Science and Fusion Center, Cambridge, United States
fDate :
5/1/2015 12:00:00 AM
Abstract :
Deploying precise optical diagnostics in harsh reactor environments poses significant engineering challenges including limited access, large forces, time-varying systematic errors, reflections, low signal-to-background levels and a need for in-situ calibration. Fielding a polarization-based Motional Stark Effect (MSE) diagnostic on Alcator C-Mod has proven to be difficult due to similar challenges, which has led to the development of solutions that enable polarization angle measurements with an accuracy of 0.2 degrees.
Keywords :
"Calibration","Plasmas","Systematics","Lenses","Optical polarization","Optical reflection","Robots"
Conference_Titel :
Fusion Engineering (SOFE), 2015 IEEE 26th Symposium on
Electronic_ISBN :
2155-9953
DOI :
10.1109/SOFE.2015.7482261