DocumentCode :
3776403
Title :
Evaluation of voltage unbalance factor for the performance analysis of induction motor
Author :
Bhola Jha
Author_Institution :
Department of Electrical Engineering, G. B. Pant Engineering College, Pauri-Garhwal, Uttarakhand 246194 India
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
This paper presents the evaluation of Complex Voltage Unbalance Factor (CVUF) on the performance of Induction motor. The assessment of motor performance in terms of copper losses, core loss, power factor, input power, efficiency, etc. are presented. Results show that the effect of phase angle of CVUF should be taken into account while calculating, core loss and copper loss. A mathematical relationship between the peak value of copper losses and core losses is illustrated. A coefficient of unbalance `f´ is inserted for estimating total copper loss, total core loss, input power, power factor, efficiency etc. in order to have precise results. The simulation results are validated using MATLAB.
Keywords :
"Copper","Induction motors","Core loss","Stator cores","Rotors","Stator windings"
Publisher :
ieee
Conference_Titel :
Systems Conference (NSC), 2015 39th National
Type :
conf
DOI :
10.1109/NATSYS.2015.7489131
Filename :
7489131