DocumentCode
3778091
Title
Comparison of the 10 V josephson voltage standards of the conventional and the programmable at NIM
Author
Li Honghui; Gao Yuan; Wang Zengmin
Author_Institution
National Institute of Metrology, Beijing 100029, China
Volume
2
fYear
2015
fDate
7/1/2015 12:00:00 AM
Firstpage
713
Lastpage
717
Abstract
A direct comparison was carried out between the Josephson voltage standard (JVS) of the National Institute of Metrology (NIM), China, and the programmable Josephson voltage standard (PJVS) available from the National Institute of Standard and Technology (NIST) at the 10 V level. The BIPM.EM-K10.b comparison protocol was applied for this comparison. It required the PJVS to provide a reference voltage for the measurement by NIM using the JVS. The paper presents the exercise performed and the comparison results. The final results were in good agreement with the relative deference of 1.8 parts in 1010 within the combined relative standard uncertainty of 4.0 parts in 1010 for the nominal voltage of 10 V.
Keywords
"Frequency measurement","Measurement uncertainty","Q measurement","Gain measurement","Uncertainty","NIST"
Publisher
ieee
Conference_Titel
Electronic Measurement & Instruments (ICEMI), 2015 12th IEEE International Conference on
Type
conf
DOI
10.1109/ICEMI.2015.7494315
Filename
7494315
Link To Document