• DocumentCode
    3778496
  • Title

    Relative humidity stabilization in a temperature controlled chamber

  • Author

    Bigliani Juan Cruz;Chesini Ezequiel;Juli?n Leandro;A. M. Taborda Ricardo

  • Author_Institution
    LIADE - Facultad de Ciencias Exactas, F?sicas y Naturales, Universidad Nacional de C?rdoba C?rdoba, Argentina
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this article an investigation is presented, where factors influencing temperature and humidity ariables in a temperature controlled chamber are analyzed. The objective of this study is to determine whether the humidity can be controlled independently of temperature in order to implement a change in the system to stabilize the relative humidity. After showing the theoretical background, the changes to be made in the chamber and the measurements that demonstrate improvements in terms of stability of relative humidity are shown.
  • Keywords
    "Humidity","Temperature","Temperature control","Media","Temperature measurement","Silicon","Humidity measurement"
  • Publisher
    ieee
  • Conference_Titel
    Information Processing and Control (RPIC), 2015 XVI Workshop on
  • Type

    conf

  • DOI
    10.1109/RPIC.2015.7497168
  • Filename
    7497168