• DocumentCode
    3780244
  • Title

    Filter design for harmonics minimization of CSI based contact less induction heater

  • Author

    Palash Pal;Pradip Kumar Sadhu;Nitai Pal

  • Author_Institution
    Department of Electrical Engineering, Indian School of Mines (Under MHRD. Govt. of India), Dhanbad, Jharkhand, India
  • fYear
    2015
  • fDate
    6/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper gives an idea to reduce the harmonics contained of current source modified half bridge inverter in the input power supply. Here, a LC low pass filter is incorporated for block the harmonics and exposed the sinusoidal input at supply end. For distinguish between fundamental and harmonics Fourier transform is used as this is a better analytical tool in the frequency domain for getting unknown signal. The simulated waveforms have been shown to justify the feasibility for real implementation of single phase current source modified half bridge inverter fed induction heater in industrial application as well as domestic application. The Total Harmonic Distortion (THD) has been significantly reduced from about 49.92% to less than 3.97% by the application of the power semiconductor Switch.
  • Publisher
    ieee
  • Conference_Titel
    Energy, Power and Environment: Towards Sustainable Growth (ICEPE), 2015 International Conference on
  • Type

    conf

  • DOI
    10.1109/EPETSG.2015.7510066
  • Filename
    7510066