DocumentCode
3781975
Title
Liquid displacement test cell for dielectric constant and dissipation factor up to 100 MC
Author
Kenneth G. Coutlee
Author_Institution
Bell Telephone Laboratories, Incorporated, Murray Hill, New Jersey, USA
fYear
1959
Firstpage
3
Lastpage
6
Abstract
The inherent high accuracy of the (1) liquid displacement test method for determining the dielectric constant of sheet insulating meterials is well established. However, there is a growing need to extend this method to a frequency range above the present maximum of 1 megacycle.
Keywords
"Dielectric constant","Capacitance","Liquids","Capacitors","Dielectric liquids","Glass","RLC circuits"
Publisher
ieee
Conference_Titel
Electrical Insulation, 1959 Conference On
Print_ISBN
978-1-5090-3136-8
Type
conf
DOI
10.1109/EIC.1959.7533347