DocumentCode
3782337
Title
Design considerations and performance evaluation of a 3 kW, soft-switched boost converter with active snubber
Author
Yungtaek Jang;M.M. Jovanovic; Chau-Chun Wen
Author_Institution
Power Electron. Lab., DELTA Products Corp., Research Triangle Park, NC, USA
fYear
1998
Firstpage
678
Lastpage
684
Abstract
The paper provides a complete design procedure of a high-power-factor (HPF) boost converter which employs an active snubber to reduce reverse-recovery related losses of the boost rectifier and achieve zero-voltage switching (ZVS) of the boost switch. The losses are reduced by inserting an inductor in the series path of the boost rectifier to reduce the di/dt rate during its turn-off. Extensive experimental evaluations of the performance of a 3 kW prototype for telecommunication applications operating from a 220 V/sub rms//spl plusmn/20% input are presented. The evaluation results demonstrate that the HPF boost converter can operate at 100 kHz switching frequency with an efficiency in the 94-97% range at full power.
Keywords
"Switches","Snubbers","Rectifiers","Inductors","Switching converters","Zero voltage switching","Telecommunication switching","Switching frequency","Capacitors","Circuits"
Publisher
ieee
Conference_Titel
Telecommunications Energy Conference, 1998. INTELEC. Twentieth International
Print_ISBN
0-7803-5069-3
Type
conf
DOI
10.1109/INTLEC.1998.793628