• DocumentCode
    3782477
  • Title

    Calibration of high precision oscillators using the TV line frequency as a frequency standard

  • Author

    M.T. Pesic;M.Z. Arsic

  • Author_Institution
    Fac. of Electron. Eng., Nis, Serbia
  • Volume
    1
  • fYear
    1999
  • Firstpage
    72
  • Abstract
    This paper describes a method for the calibration of high precision oscillators using the received TV line frequency, multiplied to 1 MHz, as a frequency standard. Since the TV system is synchronized by an atomic frequency standard, the TV line frequency preserves the excellent long-term frequency stability of the atomic reference. The phase comparison between the standard frequency and frequency of the oscillator to be calibrated is performed at 1 MHz. A complete schematic diagram of the linear phase comparator is also presented. The linearity of the comparator itself was found to be of the order of 0.1% or better. A relative frequency difference of the order of 10/sup -11/ could be measured over a period of /spl ap/1000 seconds.
  • Keywords
    "Calibration","TV","Frequency synchronization","Testing","Atomic clocks","Local oscillators","Stability","Linearity","Frequency measurement","Satellite broadcasting"
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications in Modern Satellite, Cable and Broadcasting Services, 1999. 4th International Conference on
  • Print_ISBN
    0-7803-5768-X
  • Type

    conf

  • DOI
    10.1109/TELSKS.1999.804698
  • Filename
    804698