DocumentCode
3783123
Title
Load symmetrization in supply systems with distorted line voltage
Author
D. Nedeljkovic;J. Nastran;V. Ambrozic
Author_Institution
Fac. of Electr. Eng., Ljubljana Univ., Slovenia
Volume
3
fYear
2000
Firstpage
966
Abstract
Active power filters can be successfully implemented to reduce fundamental reactive power and harmonic distortion in supply systems. Consecutively, active filters in three-phase systems can eliminate unbalance, caused by mutually noncompensated harmonic currents. Even more, with a proper control algorithm, active filters can improve symmetrical conditions of unbalanced fundamental load currents. This paper introduces a control method for a three-phase parallel active power filter. Simulation results are presented, with a special concern on the filter´s synchronization to the line voltage. Additionally, a filter can be applied as a DC source.
Keywords
"Voltage","Active filters","Power harmonic filters","Harmonic distortion","Reactive power","Inverters","Capacitors","Current supplies","Rectifiers","Power generation"
Publisher
ieee
Conference_Titel
Electrotechnical Conference, 2000. MELECON 2000. 10th Mediterranean
Print_ISBN
0-7803-6290-X
Type
conf
DOI
10.1109/MELCON.2000.879693
Filename
879693
Link To Document