DocumentCode
3783275
Title
Electrical and detection performance of radiation detector based on bulk semi-insulating InP:Fe: role of detector volume
Author
B. Zat´ko;F. Dubecky;J. Darmo;P. Euthymiou;V. Necas;M. Krempasky;M. Sekacova;D. Korytar;O. Csabay;L. Harmatha;P.G. Pelfer
Author_Institution
Inst. of Electr. Eng., Czechoslovak Acad. of Sci., Bratislava, Slovakia
fYear
2000
Firstpage
429
Lastpage
432
Abstract
In this work study of bulk semi-insulating (SI) InP:Fe-based particle detectors with emphasise to the role of detector volume is presented. Detectors based on three various materials with active contact area between 0.3-5.5 mm/sup 2/ and various base length, 190, 400, and 1830 /spl mu/m were fabricated and tested. Obtained attenuation volume ranges between 0.12 and 5.7 mm/sup 3/. Detection performance of detectors was tested at temperature 230 K. Charge collection efficiency and energy resolution tested using /spl gamma/-ray sources (/sup 241/Am, /sup 57/Co) are demonstrated. Problems of measurement at voltages >1 kV necessary for detectors with long base (>500 /spl mu/m) and architecture of a "large volume" radiation detector based on bulk SI InP applicable in detection of solar neutrino are discussed.
Keywords
"Radiation detectors","Gamma ray detection","Gamma ray detectors","Gas detectors","Silicon radiation detectors","Contacts","Materials testing","Attenuation","Temperature","Energy resolution"
Publisher
ieee
Conference_Titel
Advanced Semiconductor Devices and Microsystems, 2000. ASDAM 2000. The Third International EuroConference on
Print_ISBN
0-7803-5939-9
Type
conf
DOI
10.1109/ASDAM.2000.889537
Filename
889537