• DocumentCode
    3783442
  • Title

    Characterization of vector network analyzer coaxial calibration components

  • Author

    J. Chramiec;M. Kitlinski

  • Author_Institution
    Fac. of Marine Electr. Eng., Gdynia Maritime Acad., Poland
  • Volume
    2
  • fYear
    2000
  • Firstpage
    543
  • Abstract
    Resonance measurements have been applied in a procedure of low-loss coaxial standard components characterization. The paper outlines a method which gives not only the electrical length of the component in question but also provides data permitting us to develop the component´s equivalent circuit. Characterization results of components from 2.92 mm calibration kit have been given. The distinct advantages of the developed approach are its high accuracy and the lack of stringent requirements on the employed network analyzer calibration accuracy.
  • Keywords
    "Coaxial components","Calibration","Resonance","Frequency measurement","Connectors","Circuits","Particle measurements","Pins","Resonant frequency","Measurement standards"
  • Publisher
    ieee
  • Conference_Titel
    Microwaves, Radar and Wireless Communications. 2000. MIKON-2000. 13th International Conference on
  • Print_ISBN
    83-906662-3-5
  • Type

    conf

  • DOI
    10.1109/MIKON.2000.913991
  • Filename
    913991