DocumentCode :
3783512
Title :
Four-year performance assessment of the 342 kW PV system at Georgia Tech
Author :
M. Begovic;A. Pregelj;A. Rohatgj
Author_Institution :
Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
fYear :
2000
Firstpage :
1575
Lastpage :
1578
Abstract :
The Georgia Tech Aquatic Center photovoltaic (PV) array, one of the world´s largest roof-mounted PV arrays, has been in operation since June 1996. This paper describes the system performance during the first four years of operation. The performance is compared to the simulation results, and the modeling and forecasting accuracy improved as a result. The system failure mechanisms are identified and reliability indices, such as mean time between failures, are calculated. The overall system performance is good, and experience in operation and maintenance useful in both modeling and forecasting of the performance of PV systems of similar size.
Keywords :
"Production systems","Predictive models","Energy measurement","System performance","Temperature dependence","Databases","Photovoltaic systems","Solar power generation","Failure analysis","Maintenance"
Publisher :
ieee
Conference_Titel :
Photovoltaic Specialists Conference, 2000. Conference Record of the Twenty-Eighth IEEE
ISSN :
0160-8371
Print_ISBN :
0-7803-5772-8
Type :
conf
DOI :
10.1109/PVSC.2000.916198
Filename :
916198
Link To Document :
بازگشت