Abstract :
Two models for multiconductor transmission lines are presented that are compatible with SPICE. One model is based on a Thevenin equivalent circuit and the other model is based on mode decoupling. The models contain controlled generators in the Laplace-transform domain and are able to handle lossy lines with frequency-dependent parameters.
Keywords :