• DocumentCode
    3785154
  • Title

    Statistical analysis of electrical breakdown time delay distributions in neon tube at 13.3 mbar

  • Author

    C.A. Maluckov;J.P. Karamarkovic;M.K. Radovic

  • Author_Institution
    Tech. Fac., Univ. of Belgrade, Bor, Serbia
  • Volume
    31
  • Issue
    6
  • fYear
    2003
  • Firstpage
    1344
  • Lastpage
    1348
  • Abstract
    Results of the statistical analysis of the electrical breakdown time delay for a neon-filled tube at 13.3 mbar are presented in this paper. Experimental distributions of the breakdown time delay were established on the basis of 1000 successive and independent measurements, deviating from usual exponential distribution. Breakdown time delay distributions are numerically generated from the composition of two parameters, which correspond to the random variables of an exponential distribution and of a Gaussian distribution. Theoretical breakdown time-delay distribution is obtained from the convolution of the exponential and Gaussian distributions. The numerically generated and theoretical breakdown time delay distributions show good correspondence with the distributions of experimental data.
  • Keywords
    "Statistical analysis","Electric breakdown","Delay effects","Electrons","Gases","Ionization","Exponential distribution","Gaussian distribution","Convolution","Breakdown voltage"
  • Journal_Title
    IEEE Transactions on Plasma Science
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2003.820678
  • Filename
    1264913