DocumentCode :
3795695
Title :
A new method for measurement of safety rod drop times
Author :
M. Pesic;P. Marinkovic;D. Stefanovic
Author_Institution :
Nucl. Eng. Lab., Inst. of Nucl. Sci. VINCA, Beograd, Yugoslavia
Volume :
39
Issue :
5
fYear :
1992
Firstpage :
1502
Lastpage :
1505
Abstract :
A method for measurement of safety rod drop times is proposed that is based on a fast electromagnetic transducer and an analog-to-digital converter (ADC) connected to a computer system. Evaluation of recorded data is conducted by computer codes that were developed. The first measurements performed at the fast-thermal core HERBE constructed in the RB heavy water nuclear reactor at the Nuclear Engineering Laboratory of the Vinca Institute showed that a relative uncertainty of less than 6% can be achieved in determination of the rod drop time with time intervals ranging from 0.4 to 10.0 s.
Keywords :
"Transducers","Time measurement","Strontium","Analog-digital conversion","Performance evaluation","Inductors","Laboratories","Switches","Electrical safety","Voltage"
Journal_Title :
IEEE Transactions on Nuclear Science
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.173233
Filename :
173233
Link To Document :
بازگشت