• DocumentCode
    3796076
  • Title

    Effective control of the error in a direct measurement of core-loss power

  • Author

    F.D. Tan;J.L. Vollin;S.M. Cuk

  • Author_Institution
    Power Electron. Group, California Inst. of Technol., Pasadena, CA, USA
  • Volume
    31
  • Issue
    3
  • fYear
    1995
  • Firstpage
    2280
  • Lastpage
    2284
  • Abstract
    Accuracy of a direct measurement of core-loss power is severely limited in many applications by the extra phase shift between the measured voltage and current. An analysis of the error is for the first time performed, which not only unfolds the hidden physical nature behind it, but also reveals a simple and effective method to control the sensitivity and hence the error. This method can also be used to satisfy a prescribed tolerance. Extensive measurements on a TDK PC40 core yield results which support the analysis.
  • Keywords
    "Error correction","Power measurement","Phase measurement","Current measurement","Error analysis","Magnetic field measurement","Magnetic cores","Power electronics","Voltage","Core loss"
  • Journal_Title
    IEEE Transactions on Magnetics
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.376232
  • Filename