Case follow-up study the patients undergoing metalic heart valves replacement through phonocardiographic analysis
Author
Kemaloglu, Selma ; Kara, Sadik
Author_Institution
Biomed. Device Technol. Dept., Erciyes Univ., Kayseri, Turkey
Volume
1
fYear
2001
fDate
2001
Firstpage
169
Abstract
In this study, the synchronous pursuit of hearts sounds together with ECG signals have been realized. For this purpose pre-operative and post-operative clinical data related with the patients with heart valve diseases has been recorded through a computer. Thus, an auxiliary method has been provided to determine the patient´s health situation. Heart sounds have been obtained using a transducer insulated from its surroundings and ECG signals using surface ECG electrodes. The heart sound and ECG signals have been amplified and filtered independent of each other. After this process, these signals have been converted into digital data to be transferred to computer via I/O card. Thus, the results of heart sounds and ECG signals have been monitored and stored in the computer by software developed in Delphi Programmer Language. However, signals have been transferred in the frequency domain and a power density spectrum was drawn in order to minimize possible errors in medical diagnosis from sound signals stored in the time domain. Also, the durations of heart sound signals have been determined and the power density field has been calculated so that graphs can be compared together. The realized system has been tested with heart valve patients at the Cardiology Department in Erciyes University Gevher Nesibe Hospital
Keywords
acoustic signal processing; bioacoustics; biomedical transducers; cardiology; diseases; electrocardiography; medical signal processing; prosthetics; valves; Cardiology Department; Delphi Programmer Language; ECG signals; Erciyes University Gevher Nesibe Hospital; I/O card; case follow-up study; computer; digital data; errors; frequency domain; graphs; health situation; heart sound signal durations; heart sounds; heart valve diseases; hearts sound synchronous pursuit; medical diagnosis time domain; metallic heart valves replacement patients; phonocardiographic analysis; post-operative clinical data; power density spectrum; pre-operative clinical data; software; surface ECG electrodes; transducer; Acoustic transducers; Biomedical monitoring; Cardiac disease; Cardiovascular diseases; Computerized monitoring; Electrocardiography; Electrodes; Heart valves; Insulation; Signal processing;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
Conference_Location
Istanbul
ISSN
1094-687X
Print_ISBN
0-7803-7211-5
Type
conf
DOI
10.1109/IEMBS.2001.1018879
Filename
1018879
Link To Document