• DocumentCode
    3810616
  • Title

    Direct Measurement of AC Current by Measuring the Voltage Drop on the Coaxial Current Shunt

  • Author

    Bostjan Voljc;Matjaz Lindic;Rado Lapuh

  • Author_Institution
    Slovenian Inst. of Quality & Metrol., Ljubljana
  • Volume
    58
  • Issue
    4
  • fYear
    2009
  • fDate
    4/1/2009 12:00:00 AM
  • Firstpage
    863
  • Lastpage
    867
  • Abstract
    An accurate direct measurement of ac current that avoids complex and time-consuming ac-dc current transfer measurements by directly measuring the ac voltage drop of coaxial current shunts is described. Evaluation of custom-developed coaxial current shunts for long-term drift, self-heating effects, and loading using a commercial ac voltmeter is presented. By correcting only the shunts´ long-term drift, direct ac current measurement uncertainties below 55 muA/A are attained in the frequency range of 20 Hz-30 kHz and for currents ranging from 100 mA up to 1.0 A.
  • Keywords
    "Current measurement","Voltage measurement","Coaxial components","Electrical resistance measurement","Switches","Voltmeters","Frequency","Resistors","Metrology","Power measurement"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2008.2007074
  • Filename
    4674601