• DocumentCode
    3810641
  • Title

    Beam tests of a MWPC with CsI photocathode for Cherenkov ring imaging

  • Author

    P. Krizan;S. Korpar;M. Staric;A. Stanovnik;M. Cindro;D. Skrk;M. Zavrtanik;T. Hamacher;E. Michel

  • Author_Institution
    Jozef Stefan Inst., Ljubljana Univ., Slovenia
  • Volume
    42
  • Issue
    4
  • fYear
    1995
  • Firstpage
    590
  • Lastpage
    594
  • Abstract
    A 24/spl times/24 cm/sup 2/ asymmetric multiwire proportional chamber, with 7.5/spl times/7.5 mm/sup 2/ photosensitive CsI pads, has been tested with Cherenkov radiation of 3 GeV/c electrons in the T24 test beam at DESY. The performance of the chamber with specially designed low-noise, charge-sensitive preamplifiers is described. The parameters of the CsI-MWPC are compared to those of a TMAE photon detector in order to evaluate their potential as Ring Imaging Cherenkov (RICH) counters for the HERA-B experiment at DESY.
  • Keywords
    "Testing","Cathodes","Electron beams","Single photon emission computed tomography","Mesons","Flanges","Wires","Anodes","Radiation detectors","Signal resolution"
  • Journal_Title
    IEEE Transactions on Nuclear Science
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.467908
  • Filename
    467908