DocumentCode
3810813
Title
Calibration of Rogowski Coils at Power Frequencies Using Digital Sampling
Author
Branislav Djokic
Author_Institution
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, ON
Volume
58
Issue
4
fYear
2009
Firstpage
751
Lastpage
755
Abstract
A new high-accuracy system for power-frequency calibration of Rogowski coils is described in this paper. The calibration system is based on nonsynchronous digital sampling. An automated prototype of the calibration system operates at currents of up to 2000 A. A semiautomated system is capable of operating at currents of up to 60 000 A. The best uncertainty (k = 2) of the calibration system is estimated to be better than 50 muA/A for magnitude and 50 murad for phase.