• DocumentCode
    3812906
  • Title

    Voltage-Fluctuation-Based Identification of Noxious Loads in Power Network

  • Author

    Grzegorz Wiczynski

  • Author_Institution
    Metrol. & Optoelectron. Div., Poznan Univ. of Technol., Poznan, Poland
  • Volume
    58
  • Issue
    8
  • fYear
    2009
  • Firstpage
    2893
  • Lastpage
    2898
  • Abstract
    Very often, voltage fluctuations can cause a decrease in power quality. It is possible to improve this quality by changing the characteristics of the fluctuation source and/or the supply circuit. To do so, it is necessary to find the source of a given fluctuation and determine its properties. The problem-causing loads are most often identified through the analysis of fluctuation amplitude variations. Less popular is a method that compares the variations of the current with the variations of the voltage fluctuation indices. In this paper, both methods are described, and their properties are compared.
  • Keywords
    "Voltage fluctuations","Circuits","Power quality","Power supplies","Time measurement","Furnaces","Electrothermal effects","Electronic equipment","Metrology","Network topology"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2009.2016373
  • Filename
    4840490