DocumentCode :
381826
Title :
A new analytical model for detectivity prediction of resistance bolometers
Author :
Kohl, Franz ; Keplinger, Franz ; Jachimowicz, Artur ; Chabicovsky, Rupert
Author_Institution :
Ludwig Boltzmann Inst. of Biomed. Microtechnology, Vienna, Austria
Volume :
2
fYear :
2002
fDate :
2002
Firstpage :
1290
Abstract :
A new model of room temperature resistance bolometers is described, which includes all effects of electrothermal coupling. It is based on one main operating parameter named thermal bias and offers a simple way to find optimal operating conditions for a certain bolometer construction. The model yields reliable estimates of the achievable NEP and detectivity D* for a given bolometer design and it enables the comparison of competing technologies namely with respect to the thermistor material employed.
Keywords :
bolometers; analytical model; detectivity; electrothermal coupling; noise equivalent power; room temperature resistance bolometer; thermal bias; thermistor material; Analytical models; Bolometers; Electrical resistance measurement; Electrothermal effects; Immune system; Resistance heating; Resistors; Temperature sensors; Thermal resistance; Thermistors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2002. Proceedings of IEEE
Print_ISBN :
0-7803-7454-1
Type :
conf
DOI :
10.1109/ICSENS.2002.1037303
Filename :
1037303
Link To Document :
بازگشت