DocumentCode :
3833880
Title :
Crossfield Sensitivity in AMR Sensors
Author :
Pavel Ripka;Michal Janosek;Mattia Butta
Author_Institution :
Dept. of Meas., Czech Tech. Univ. in Prague, Prague, Czech Republic
Volume :
45
Issue :
10
fYear :
2009
Firstpage :
4514
Lastpage :
4517
Abstract :
We discuss the origin of the crossfield sensitivity of AMR sensors, the way how this error may influence the performance of an AMR compass and methods for its correction. Finally, we confirm the simple formulas experimentally. Crossfield may cause compass error up to 2.6 deg., depending on the compass orientation. The most effective way to suppress the crossfield error is using magnetic feedback, however this is not always possible. We suggest a method of processing of the SET/RESET sensor outputs which is more efficient than the usual averaging.
Keywords :
"Magnetic sensors","Anisotropic magnetoresistance","Azimuth","Magnetic anisotropy","Perpendicular magnetic anisotropy","Error correction","Sensor systems","Electric variables measurement","Feedback","Magnetic materials"
Journal_Title :
IEEE Transactions on Magnetics
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2009.2022051
Filename :
5257125
Link To Document :
بازگشت