DocumentCode
384542
Title
Response of a narrow band PD detector and analyzer in ageing experiments
Author
Kumar, S. Senthil ; Nerkar, Y.P. ; Narayanachar, M.N. ; Nema, R.S.
Author_Institution
Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
fYear
2002
fDate
2002
Firstpage
720
Lastpage
723
Abstract
Partial discharge (PD) pulses are recorded with an analyzer connected to a PD detector. The analyzer presents PD data as distributions that are used to interpret the PD phenomenon. The paper describes results of ageing experiments on oil impregnated pressboard samples subjected to PD measured with a narrow band detector and analyzer system. The main focus of the paper is on instrumentation related with narrow band detector and analyzer. A detailed response study of the narrow band detector is carried out to understand its behavior with pulses appearing with different repetition rate. The paper discusses characterization of PD distributions for meaningful interpretation.
Keywords
ageing; impregnated insulation; insulation testing; partial discharge measurement; ageing process; analyzer system; insulation diagnosis; measurement instrumentation; narrow-band PD detector; oil impregnated pressboard; partial discharge pulse; repetition rate; Aging; Detectors; Filters; Instruments; Narrowband; Partial discharges; Pulse amplifiers; Pulse shaping methods; Time measurement; Wideband;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
Print_ISBN
0-7803-7502-5
Type
conf
DOI
10.1109/CEIDP.2002.1048897
Filename
1048897
Link To Document