• DocumentCode
    3846715
  • Title

    Calibration of Rogowski Coils at Frequencies up to 10 kHz Using Digital Sampling

  • Author

    Branislav Djokic

  • Author_Institution
    Institute for National Measurement Standards, National Research Council of Canada , Ottawa, Canada
  • Volume
    59
  • Issue
    5
  • fYear
    2010
  • Firstpage
    1303
  • Lastpage
    1308
  • Abstract
    A new system for calibration of Rogowski coils at frequencies up to 10 kHz, based on a reference current transformer, a reference ac shunt, and a digital sampling system, is described in the paper. The calibration system has been automated, and its performance has been evaluated. At the frequency of 10 kHz, the calibration system is capable of generating currents up to 100 A. At power frequencies, it is capable of generating currents up to 2000 A. The best uncertainties (k = 2) of the calibration system are estimated to be less than 500 ?A/A for magnitude and 500 ?rad for phase at 10 kHz and an order of magnitude better at power frequencies.
  • Keywords
    "Calibration","Coils","Sampling methods","Current transformers","Frequency estimation","Plasma measurements","Uncertainty","Discrete Fourier transforms","Power generation","Current measurement"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2009.2038029
  • Filename
    5443515