DocumentCode :
384722
Title :
Hearing aid based on frequency transposing
Author :
Mota-Gonzalez, G. ; Cardiel, Eladio ; Pablo-Ro, Hedz
Author_Institution :
Departamento de Ingenieria Electrica, Centro de Investigacion y de Estudios Avanzados, IPN, Mexico City, Mexico
Volume :
3
fYear :
2002
fDate :
23-26 Oct. 2002
Firstpage :
2432
Abstract :
In this work a hearing aid based on frequency transposing is presented. It aims to take advantage from the residual low frequency sensitivity in age-related hearing loss cases. Moreover, it has been reported that the use of excessive amplification could induce a degenerative process in the auditory system. Frequency transposing is carried out using a frequency dividing method. The aid is intended for voice applications. Thus, audio signal is amplified under a compression process and filtered in 300-3400 Hz range. The audio signal processing was preliminarily performed using Matlab for adjusting and evaluating and the digital part of the aid was finally implemented using a Digital Signal Processor.
Keywords :
data compression; hearing aids; medical signal processing; speech processing; 300 to 3400 Hz; Matlab; auditory system; degenerative process; digital signal processing; excessive amplification; frequency dividing method; frequency transposing; hearing loss; voice applications; Auditory system; Biomedical signal processing; Deafness; Digital signal processing; Digital signal processors; Frequency conversion; Performance evaluation; Signal processing; Signal processing algorithms; Speech;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint
ISSN :
1094-687X
Print_ISBN :
0-7803-7612-9
Type :
conf
DOI :
10.1109/IEMBS.2002.1053360
Filename :
1053360
Link To Document :
بازگشت