DocumentCode
3849978
Title
Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines
Author
Carlos A. Platero;F. Blázquez;Pablo Frías;Dionisio Ramírez
Author_Institution
Electrical Engineering Department, Escuela Té
Volume
26
Issue
2
fYear
2011
Firstpage
671
Lastpage
676
Abstract
Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.
Keywords
"Rotors","Circuit faults","Windings","Stator windings","Synchronous machines","Resistance","Rotating machines"
Journal_Title
IEEE Transactions on Energy Conversion
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/TEC.2011.2106214
Filename
5720292
Link To Document