• DocumentCode
    3849978
  • Title

    Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines

  • Author

    Carlos A. Platero;F. Blázquez;Pablo Frías;Dionisio Ramírez

  • Author_Institution
    Electrical Engineering Department, Escuela Té
  • Volume
    26
  • Issue
    2
  • fYear
    2011
  • Firstpage
    671
  • Lastpage
    676
  • Abstract
    Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.
  • Keywords
    "Rotors","Circuit faults","Windings","Stator windings","Synchronous machines","Resistance","Rotating machines"
  • Journal_Title
    IEEE Transactions on Energy Conversion
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2011.2106214
  • Filename
    5720292