• DocumentCode
    3850044
  • Title

    Phase Comparison of High-Current Shunts up to 100 kHz

  • Author

    Gian Carlo Bosco;Martin Garcocz;Kåre ;Umberto Pogliano;Gert Rietveld;Valter Tarasso;Boštjan ;Věra Nováková Zachovalová

  • Author_Institution
    Electromagnetics Division, Istituto Nationale di Ricerca Metrologica (INRIM), Torino, Italy
  • Volume
    60
  • Issue
    7
  • fYear
    2011
  • fDate
    7/1/2011 12:00:00 AM
  • Firstpage
    2359
  • Lastpage
    2365
  • Abstract
    A comparison of the phase error of existing shunts for currents between 10 and 100 A and frequencies from 500 Hz to 100 kHz has been organized. Measurement processes were performed at Istituto Nationale di Ricerca Metrologica on some shunts using the first prototype of a new type of a phase comparator and a step-up method for data processing. Results of the relative measurement processes have shown good repeatability. The method for evaluation of reference values was based on similar shunts and suitable assumptions and derived by extrapolation. For the type of resistance elements employed in these shunts, the derivation of the reference is not very accurate and still needs to be improved.
  • Keywords
    "Phase measurement","Current measurement","Frequency measurement","Uncertainty","Electrical resistance measurement","Measurement uncertainty","Voltage measurement"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2011.2108553
  • Filename
    5728913