Title :
Phase measurement of distorted periodic signals based on nonsynchronous digital filtering
Author_Institution :
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
Abstract :
Measurement of the phase angle between fundamental components of distorted periodic signals at power frequencies is described. It is based on a nonsynchronous multirate digital filtering algorithm, which is applied to the voltage and/or current signals to be measured. The digital filters implemented are designed to suppress the higher harmonics and ensure the accuracy of measurement. The measurement method is insensitive to frequency variations in a wide frequency band around the nominal frequency. For a frequency band of /spl plusmn/10% around the nominal frequency, this method can resolve phase differences of less than 5 /spl mu/rad with an uncertainty of less than /spl plusmn/25 /spl mu/rad.
Keywords :
"Phase measurement","Phase distortion","Distortion measurement","Frequency measurement","Power measurement","Filtering algorithms","Voltage","Current measurement","Digital filters","Power harmonic filters"
Journal_Title :
IEEE Transactions on Instrumentation and Measurement