Abstract :
An industrial motor drive suffers from periodic failures of the DC link aluminum electrolytic capacitor bank. Simulations pinpoint likely causes, including problems with the design of the balancing resistors. Stress on the capacitor can be produced by faults in the inverter and by open-conductor faults in the balancing resistors.
Keywords :
capacitor storage; electrical faults; electrolytic capacitors; induction motor drives; invertors; resistors; steel industry; 13.8 kV; 1500 kVA; 1500 kW; 700 V; 950 V; DC link aluminum electrolytic capacitor bank; balancing resistors; capacitor stress; industrial AC drive system; industrial motor drive; inverter faults; open-conductor faults; periodic failures; steel industry; AC motors; Capacitors; Circuit faults; Inverters; Metals industry; Motor drives; Rectifiers; Resistors; Synchronous motors; Voltage;