DocumentCode
391426
Title
Stability analysis of systems with nonsymmetric dead zone under fuzzy logic control
Author
Wong, L.K. ; Leung, F.H.F. ; Tam, P.K.S.
Author_Institution
Centre for Multimedia Signal Process., Hong Kong Polytech. Univ., China
Volume
3
fYear
2002
fDate
5-8 Nov. 2002
Firstpage
2114
Abstract
Many existing stability analysis methods for fuzzy logic control systems like TS fuzzy model based methods usually tackle plants that are linear with respect to control. However, these methods may be difficult to apply to plants with dead zones. This paper presents an improved stability analysis method to resolve this difficulty. Our proposed method employs a Lyapunov function to prove the stability of nonlinear fuzzy logic control systems with asymmetric dead zone and saturation. An illustrative example will be given to demonstrate the ability of the method.
Keywords
Lyapunov methods; fuzzy control; industrial control; nonlinear control systems; stability; Lyapunov function; asymmetric dead zone; fuzzy logic control; industrial control systems; nonlinear fuzzy logic control systems; nonsymmetric dead zone; saturation; stability analysis; stability analysis method; Control system synthesis; Control systems; Fuzzy control; Fuzzy logic; Fuzzy systems; Lyapunov method; Multimedia systems; Robustness; Stability analysis; Steady-state;
fLanguage
English
Publisher
ieee
Conference_Titel
IECON 02 [Industrial Electronics Society, IEEE 2002 28th Annual Conference of the]
Print_ISBN
0-7803-7474-6
Type
conf
DOI
10.1109/IECON.2002.1185299
Filename
1185299
Link To Document