DocumentCode
393615
Title
On the high accurate mass calibration of 50 kg weights
Author
Sun, Jianxin ; Ueki, Masaaki ; Mizushima, Shigeki ; Ueda, Kazunaga ; Ooiwa, Akira
Author_Institution
Nat. Inst. of Adv. Ind. Sci. & Technol., Japan
Volume
1
fYear
2002
fDate
5-7 Aug. 2002
Firstpage
489
Abstract
This paper concerns the high accurate mass calibration of 50 kg weights. Applying Gauss´ double weighing method, the result of calibration is independent of the mass values of the weighing pans, which are used for holding the weights. This paper reports on the calibration method and the uncertainty calculations.
Keywords