Title :
Concentration and Temperature Tomography at Elevated Pressures
Author :
Wood, Michael P. ; Ozanyan, Krikor B.
Author_Institution :
Sch. of Electr. & Electron. Eng., Univ. of Manchester, Manchester, UK
Abstract :
Computer simulations are used to introduce a new approach to measure temperature fields of a gas using laser attenuation measurements, which exhibits good theoretical accuracy despite very high static pressures. Near-infrared laser light is used to target specific molecular absorption lines of water vapor, whose strength depends (nonlinearly) on the gas temperature. This temperature can be inferred when multiple laser paths coincide nearby by tomographic reconstruction of the attenuation coefficient and then spectral fitting to local temperature, species concentration, and gas pressure. Temperature phantoms (invented distributions for the purpose of numerical testing) are used to simulate experimental results, which are then contaminated with Gaussian noise and used to reconstruct the temperature field. The root-mean-square reconstruction temperature error varied from ~0.4%, in no Gaussian noise and at 1 bar, to 2.2%, in 5% noise and at 50 bar.
Keywords :
computerised tomography; image reconstruction; measurement by laser beam; temperature measurement; Gaussian noise; attenuation coefficient; computer simulations; concentration tomography; elevated pressures; gas temperature; laser attenuation measurements; multiple laser paths; near-infrared laser light; spectral fitting; temperature fields; temperature tomography; very high static pressures; Computed tomography; Landweber reconstruction; molecular absorption; temperature measurement;
Journal_Title :
Sensors Journal, IEEE
DOI :
10.1109/JSEN.2013.2260535