• DocumentCode
    397194
  • Title

    Speeding-up dynamic response of active power conditioners

  • Author

    Silva, Luiz Eduardo Borges da ; de Lacerda de Oliveira, Levy Ely ; Silva, Valberto Ferreira da ; Torres, Germano Lambert ; Bonaldi, Erik Leandro ; Rossi, Ronaldo

  • Author_Institution
    Taubate Univ., Brazil
  • Volume
    1
  • fYear
    2003
  • fDate
    4-7 May 2003
  • Firstpage
    347
  • Abstract
    The id-iq control method is one of the most widespread control methods for active power filters. Two improvements to this method are presented: the elimination of the PLL (phase locked loop) in active power filters for harmonic current compensation only and a strategy for achieving the best transient time. PLL elimination is an important simplification for reducing the computational effort in a digital implementation as well as for improving transient time. The achievement of the best transient time is essential for an efficient compensation of currents with time-varying harmonic content. The paper describes both improvements and presents simulations and experimental results.
  • Keywords
    active filters; dynamic response; moving average processes; phase locked loops; power harmonic filters; PLL; active power conditioners; active power filters; dynamic response; harmonic power compensation; id-iq control method; moving average technique; phase locked loops; time-varying harmonic content; Active filters; Computational modeling; Current supplies; Low pass filters; Phase locked loops; Power harmonic filters; Power system harmonics; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Computer Engineering, 2003. IEEE CCECE 2003. Canadian Conference on
  • ISSN
    0840-7789
  • Print_ISBN
    0-7803-7781-8
  • Type

    conf

  • DOI
    10.1109/CCECE.2003.1226412
  • Filename
    1226412