DocumentCode
399918
Title
Measurements of thermal frequency chirp in directly modulated DFB lasers and thermal transient induced frequency drift during fast tuning in GCSR lasers using frequency discrimination technique
Author
Buimovich, Efraim ; Sadot, Dan
Author_Institution
Electr. & Comput. Eng. Dept., Ben Gurion Univ., Beer-Sheva, Israel
Volume
1
fYear
2003
fDate
27-28 Oct. 2003
Firstpage
208
Abstract
Frequency deviations in a regime of high rate current fluctuations in distributed feedback (DFB) and grating coupler sample reflector (GCSR) lasers are measured using novel statistical frequency discrimination technique. Thermal time constants of the order of nanoseconds are observed in both.
Keywords
chirp modulation; diffraction gratings; distributed feedback lasers; electro-optical modulation; laser tuning; optical couplers; optical testing; semiconductor device testing; semiconductor lasers; statistical analysis; GCSR lasers; directly modulated DFB lasers; distributed feedback laser; fast tuning; frequency deviations; frequency discrimination technique; grating coupled sample reflector laser; high rate current fluctuations; thermal frequency chirp; thermal time constants; thermal transient induced frequency drift; Bit rate; Chirp modulation; Crosstalk; Current measurement; Frequency measurement; Frequency modulation; Laser tuning; Signal analysis; Time measurement; Wavelength measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Lasers and Electro-Optics Society, 2003. LEOS 2003. The 16th Annual Meeting of the IEEE
ISSN
1092-8081
Print_ISBN
0-7803-7888-1
Type
conf
DOI
10.1109/LEOS.2003.1251708
Filename
1251708
Link To Document