• DocumentCode
    400714
  • Title

    Steady-state and dynamic study of one-cycle controlled three-phase active power filter

  • Author

    Chen, Guozhu ; Smedley, Keyue M.

  • Volume
    2
  • fYear
    2003
  • fDate
    12-16 Oct. 2003
  • Firstpage
    1075
  • Abstract
    One-cycle control active power filter (OCC-APF) with vector operation is a promising method to cancel harmonics and correct power factor. It features simple circuit, high performance, and excellent stability. This paper studies the performances of both the steady-state and dynamics. The stability condition for three-phase OCC-APF is first derived. Some typical large signal perturbations and the tracking ability for the fast transient are investigated, which provides guidelines for the design of the control circuit and the main circuit. All analysis and results were verified by simulation and experiments based on a three-phase 5 kW pre-industrial OCC-APF prototype.
  • Keywords
    active filters; power factor correction; power harmonic filters; power system harmonics; power system transients; stability; 5 kW; dynamics; fast transient; harmonics cancellation; one-cycle controlled three-phase active power filter; power factor correction; signal perturbations; stability; tracking ability; vector operation; Active filters; Analytical models; Circuit analysis; Circuit stability; Guidelines; Power harmonic filters; Power system harmonics; Reactive power; Signal design; Steady-state;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Conference, 2003. 38th IAS Annual Meeting. Conference Record of the
  • Print_ISBN
    0-7803-7883-0
  • Type

    conf

  • DOI
    10.1109/IAS.2003.1257682
  • Filename
    1257682