DocumentCode :
402254
Title :
Measuring absolute group delay of multistage converters
Author :
Ballo, D.
Author_Institution :
Agilent Technol., Santa Rosa, CA, USA
Volume :
1
fYear :
2003
fDate :
7-9 Oct. 2003
Firstpage :
89
Abstract :
This paper describes new calibration and measurement techniques for measuring absolute group delay of frequency converters with multiple mixing stages. The calibration methodology used is Agilent\´s Vector Mixer Calibration (VMC), where reflection measurements are used to characterize a calibration mixer, which is then used as a characterized through adapter to calibrate a frequency-translating test system for absolute magnitude and phase. The measurement methodology includes the use of a "meta-LO", which is a local oscillator derived from the LOs used for the converter under test. The meta-LO drives a reference mixer and the calibration mixer. For converters employing embedded LOs for which there is no access, but where access to a common time base is provided, an alternative measurement methodology is described.
Keywords :
calibration; microwave frequency convertors; microwave mixers; microwave reflectometry; network analysers; absolute group delay measurements; calibration mixer; conversion loss; dual-stage converter; frequency converters; frequency-translating test system; multiple mixing stages; multistage converters; reference mixer; reflection measurements; vector mixer calibration; Calibration; Delay; Frequency conversion; Frequency measurement; Local oscillators; Measurement techniques; Mixers; Phase measurement; Reflection; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 2003. 33rd European
Print_ISBN :
1-58053-834-7
Type :
conf
DOI :
10.1109/EUMC.2003.1262225
Filename :
1262225
Link To Document :
بازگشت