DocumentCode
403587
Title
Thermal and power integrity based power/ground networks optimization
Author
Ting-Yuan Wang ; Tsai, Jeng-Liang ; Chen, Charlie Chung-Ping
Author_Institution
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
Volume
2
fYear
2004
fDate
16-20 Feb. 2004
Firstpage
830
Abstract
With the increasing power density and heat-dissipation cost of modern VLSI designs, thermal and power integrity has become serious concern. Although the impacts of thermal effects on transistor and interconnect performance are well-studied, the interactions between power-delivery and thermal effects are not clear. As a result, power-delivery design without thermal consideration may cause soft-error, reliability degradation, and even premature chip failures. In this paper, we propose a thermal-aware power-delivery optimization algorithm. By simultaneously considering thermal and power integrity, we are able to achieve high power supply quality and thermal reliability. For a 58×72 mesh as shown in the experimental results, our algorithm shows that the lifetime of the optimized ground network is 9.5 years. Whereas the lifetime of the ground network generated by a traditional method is only 2 years without thermal concern.
Keywords
electromigration; optimisation; power supply quality; power transmission reliability; 9.5 year; VLSI designs; electromigration; power integrity; power/ground network optimization; thermal aware power delivery optimization algorithm; thermal effects; thermal integrity; thermal reliability; very large scale integration design; Current density; Design methodology; Electromigration; Energy consumption; Thermal degradation; Thermal management; Timing; Very large scale integration; Voltage; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Design, Automation and Test in Europe Conference and Exhibition, 2004. Proceedings
ISSN
1530-1591
Print_ISBN
0-7695-2085-5
Type
conf
DOI
10.1109/DATE.2004.1268986
Filename
1268986
Link To Document